placement gauges. This reflects their high quality engineering, improved reliability and relative ease of use. It offers various placement techniques (Step, Roth, Wick Alexander, Dwight Damon, MBT, Andrews) and, in combination with the clear aligner module, allows to construct several types of trays for the transfer of the brackets in the mouth of. Then etching the labial surfaces. Twin brackets are used on u. 5 mm from incisal edge. designed for durability with Ormco’s elastics and auxiliaries. Ormco's Straight-Wire® Synthesis™ brackets are designed to mirror the anatomy of the middle third of each tooth to ensure accurate placement and a snug fit. 1: Customized group: Pre-treatment extra. The result is a crystal-clear appliance that goes beyond all aesthetic and functional expectations. Instrumentsmall initial arch wires and the 0. Where should braces brackets be placed. E-mail address: drshoaibkhan. More studies are needed in order to perform a systematic review or meta-analysis on the comparison of non. 025″ SS and TMA wires, respectively, at an interbracket. Instructions for Using Damon™ Optimal-Force Copper Ni-Ti ® with Preloaded Stops Archwire Stops • Cut the Copper Ni-Ti archwire to proper length. 25 Nmm and 7. 0 Nmm for the Hanson speed (ASL) bracket, and 7. only make archwire placement more convenient and secure, but also have lower kinetic frictional force than conventional brackets. and for the Damon 2 (PSL) brackets, it was 2. The pre-treatment. A common orthodontic task is to correct anterior tooth position using brackets whose torque, tip and in-out are pre-adjusted. -6 90 -11 70 3-3 standard t. Convenient use of . Max Central = 5 6 mm from incisal edge. nine bracket positioning in relation to the incisors. Ample under tie-wing area accommodates all powerchain, elastics, steel ligatures, and other auxiliaries. Damon 2. 022 × 0. 043" 497-6475 497-6474 **For use with Damon Clear, Damon Q™ and SnapLink™. 022L . Errors in bracket position could lead to an This case report was done to check the clinical guide for ver- improper finish, hampered esthetics and altered function of tical positioning of the bracket. The FAQ. The results indicate that Morina et al. This is why the table is titled Guide to Position Smile-Arc (GPS-A). DAMON SYSTEM • The Damon System (Ormco Corp. Five orthodontic residents were recruited to bond brackets on the same 3D-printed copies of resin models in a dental mannequin using GBD-Us and GBD-Bs, respectively. Damon Torque and Bracket Placement Guide - Free download as PDF File (. n/a 0 3 22. Offering a complete and interchangeable system of metal and aesthetic appliances, Damon™ Q2 functions seamlessly with: Damon™ Q. The digital tools in Insignia’s Approver software enable you to simulate the final desired result at the beginning of treatment. Both ways can work, but in some cases, braces are a better choice,” says Dr. drop-in hooks * and optional permanent hooks designed for durability with Ormco’s elastics and auxiliaries. Errors in bracket position could lead to an This case report was done to check the clinical guide for ver- improper finish, hampered esthetics and altered function of tical positioning of the bracket. 018”×0. 25 Nmm and 7. With ODB, streamline daily workflow & achieve customized bracket positioning by leveraging Damon Ultima™ brackets & the Spark Approver Software. All positioning gauges are colour-coded to aid in bracket selection and torque value identification: Green for low torque, Blue for standard torque, red for super torque. Proven efficiency. The brackets placement module allows to automatically place the brackets on the teeth. SmartArch . • Rhomboid-shaped bracket and pad and vertical scribe line for smile arc enhancement Damon System Damon Q Damon Q is a major step forward in low-friction, passive self-ligation technology that delivers far more than straight teeth. 02345” ± 0. Call Ormco Customer Care at 1-800-854-1741. The indirect bonding appointment will be completed by the assigned resident, at which time the. Redmond MJ, Redmond WR: The OrthoCAD bracket placement solution. Orthodontic treatment is now less time-consuming and more comfortable than ever before. A new table to guide bracket placement based on the concept of “smile arc protection” Published on September 6, 2014 by Orthodontic Practice Drs. * Current Damon Q drop-in hooks (242-0114) are compatible with Damon Q2 brackets. Dwight Damon. Variation in bracket positioning alters the. Damon Q brackets generated higher torque values compared to Smart Clip brackets with both SS and TMA wires. 1-1. Volver a los productos Kit Damon Q S/I Torque Bajo $ 5,944. Seamless Compatibility With The Damon System. • The mesiodistal width of the pad and the. This is when he created the Pitts 21 passive self-ligating orthodontic brackets with smaller than ever square slots, with a depth of 0. 516. Appliance Systems Digital Systems Buccal Tubes Adhesives, Cements & Primers Elastics & Power Products Extraoral Appliances Practice Management ORTHODONTIC PRODUCTS CATALOG ormco | your practice. 28); p = 0. 2008. Subscribe to Our Notifications. The metal Damon Q is a major step forward in low-friction, passive self-ligation technology that delivers far more than straight teeth. 5 mm from incisal edge. Allows for convenient placement of drop-in hooks. Damon System Clinical Reference Guide - Vol. help guide bracket placement. Figure s howing placement of brackets in the m axillary anteriors. 5 5. 3 & 4 Std. Precision Bracket Placement. Scaler Notch Low Torque. All positioning gauges are colour-coded to aid in bracket selection and torque value identification: Green for low torque, Blue for standard torque, red for super torque. We determined the positions of brackets in 28 teeth of 15 cases according to positioning methods that use bracket height or root information. Rp1. The Damon Q's base was reported at 0. 4. Marcos Freitas Dr. 016”×0. 72 Nmm and 7. 025 in. The elastic bands in traditional braces can become dirty easily. 033"* . Damon ™ Q . The rounded structure improves patient comfort while maintaining overall performance. The crimpable hook placement is at the distal of lateral incisor on SS 0,019 x 0,025working wire. 0275” at the height of its radius (Figure 3), which provides simultaneous. Damon Clear 2 combines the properties of low friction passive self-ligating technology with the aesthetics that image-conscious patients demand. both the mandibular molars are pla ced at th e same heig ht, which is 0. Patients preferred the look of the twin bracket over the Damon 2 (P, . drop-in hooks * and optional permanent hooks designed for durability with Ormco’s elastics and auxiliaries. With the Damon Ultima System, brackets are designed for center-point slot alignment at the FA point for desired torque expression and easier, more precise bracket placement. However, precise bracket placement still relies on the professional’s individual skills and the accuracy of bonding procedures [1-3]. El nuevo bracket metálico Damon Q es un gran paso en la tecnología de baja fricción y autoligado pasivo que brinda mucho más que dientes alineados. 019 x . Damon Braces can work faster than clear aligners for many orthodontic cases. In both the MBT and Damon brackets, the results for Score 3 were 0%. Perio & Surgery. The original and Damon Q braces are metal based self-ligating brackets with a unique clip mechanism in holding the archwire. t orquew i play, dv ng x s. By resolving the most difficult part of treatment first, you can achieve a. of 12 Quick Reference Guide DAMON™ Q TORQUE SELECTION GUIDE One of the most important clinical principles to succeed with the Damon System is to select the right. Vertical scribe line, new drop-in hook, and modified prescription — DQ2 features a rhomboid-shaped pad and new vertical scribe line to guide desired bracket placement. Effect of Bracket Position on Wire Plane If a full enamel display with 1-1. Visitenos. Damon ™ Q2. Our first DIBS indirect bonding case went perfectly with no bond failures. Instructions for Using Damon™ Optimal-Force Copper Ni-Ti ® with Preloaded Stops Archwire Stops • Cut the Copper Ni-Ti archwire to proper length. 02337” ± 0. Join for free. Tom Pitts with an emphasis on smile arc. Treatment results were assessed with American board of orthodontics objective grading system (ABO-OGS). The DQ2 is the newest addition to the Damon™ System and this passive self-ligating bracket, when compared to the Damon Q, features two times the rotational control and. AZDENT 8G very small DAMON Q STYLE Metal self ligating bracket. Nigel Harradine The History and Development of Self-Ligating Brackets Seminars in Orthodontics, Vol 14, No 1 (March), 2008: pp 5-18 5. Recently, technological advances have improved the indirect method by. showed, Damon Q (PSL) brackets with mean torque varied from 8. 89 – 62. Upper . drop-in hooks * and optional permanent hooks designed for durability with Ormco’s elastics and auxiliaries. Damon Q2 brackets are recommended for adolescents and adults for cases of low or high complexity, together with the computer-assisted indirect placement technique, offers the. Search life-sciences literature (41,860,896 articles, preprints and more) Search. 025″ SS and TMA wires, respectively, at an interbracket. 071 mm. Find standings and the full 2023 season schedule. Castellanos, in Contemporary Esthetic Dentistry, 2012. 3 & 4 Std. It is completely reengineered to virtually eliminate play for precise control of rotation, angulation and torque. Damon. Overview. 5 5. Click. Contact your Ormco Sales Representative. DIBS has transformed my practice. It is completely reengineered to virtually eliminate play for precise control of rotation, angulation and torque. 028"* Reduced play in the slot of SLX Brackets improves first order control, as well as torque and rotational control, for more precise tooth positioning and faster, better finishes. help guide bracket placement. 5 5. Today the metal Damon Q has come a long way, with very reliable clinical per-formance. Damon ™ Q2. Tomás Castellanos and Thomas Pitts. 3Shape, Copenhagen, Denmark, announced its indirect bonding solution now integrates with the Damon ™ System Bracket library from Ormco Corp, Orange, Calif. Damon ™ SL. 100% clear bracket body and slide. 572 mm (0. Bracket prescription greatly influences final. 071 mm. 2005. Education Lab Products CONTINUED ON BACK BRACKET PLACEMENT GUIDE A clinician can place the upper and lower mid-bracket slot within the green lines without dramatically impacting torque Take advantage of the engineering ZONE MID CROWN Max Central = 5 – 6 mm from incisal edge Max Lateral = 4. 022” slot of the Damon Q bracket, where full engagement against the slot base is non-existent due to the nature of the locking mechanism’s “passive” construction. Jual Bracket Damon Terbaik - Harga Murah November 2023 & Cicil 0%. 071 mm. 019 × 0. EasyinSmile Damon Q Style metal Self ligating bracket Roth 0. Interactivity Guide Time 302. 45 Nmm, while Smart Clip brackets generated 22. Convenient. Ormco Kit Damon Q U/I Torque Alto $ 5,944. The most significant technologic advancement is the self-ligating bracket. Dr. The effectiveness is measured by: 1. The Damon Q brackets had slot widths of 0. 2004. In clear ceramic braces from Damon clear© they have recently developed the Damon Clear 2© system. Comparison of . 2. The patient was diagnosed with normodivergent face pattern, proclined upper anterior, and crowded lower anterior, concave profile, potentially competent lips, reverse overjet and 0% overbite, and shallow mentolabial sulcus. The Damon Clear bracket outperformed design specifications of the Damon 3 bracket as well exceeded many performance specifications of In-Ovation C. It is also very convenient when you have an inversion of the upper centrals and laterals and it is impossible to put brackets on these teeth. • Position the archwire stops at the desired location, typically at or near the midline (anterior to crowding). 022-in Damon Q brackets (Ormco, Glendora, Calif) in this study. 2005. Damon Q brackets are the most rectangular in shape, with nearly 90-degree corners between the slot bottom and walls. And from those norms, the MBT System bracket placement process offers an efficient, standardized means for achieving intra-arch accuracy along the vertical axis. Each positioning gauge is color-coded to aid in bracket selection and torque value identification. bracket slide. 72 Nmm and 7. But where the braces are placed can impact the curvature of the smile. BRACKET SELF LIGATING bracket damon with buccal Tube & Dental cuniti. 72 Nmm and 7. Damon braces use wires and brackets, while Invisalign uses a series of clear aligner trays that fit over your teeth and gradually move them into the desired position. Brainerd Swain in 1949, to overcome the problem of root parallelism in extraction cases. 019 X . It is completely reengineered to virtually eliminate play for precise control of rotation, angulation and torque. pdf), Text File (. Damon Q brackets generated the highest torquing moment of 25. Ordinarily, archwires can be inserted with the fingertips and the slides will close easily, either with a finger (Damon3) or with a Damon Universal Plier (Damon2). 2 low t. 8K views 6 years ago. Warnings. Speckling pattern as seen with an archwire with (a) the RD and (b) with a Damon Q bracket. 016x0. 025 SS and TMA wires, respectively, at an interbracket. 022 Final wires: upper SS Damon . I develop a detailed bonding plan prior to the bonding appointment and carefully select torques. Beyond the accuracy or inaccuracy of bracket placement and the fact that. 0215. The Damon System is a name brand of self-ligating braces available in two different types: self-ligating. Need help? Drop us a note and we’ll be in touch. The bracket system’s rhomboid-shaped pad and new vertical scribe line help guide desired bracket placement, while the DQ2 drop-in hook provides improved bending strength and durability with Ormco’s elastics and auxiliaries. To achieve this, we place the brackets slightly higher and with a gradual, natural step in. Green: Low Torque; Blue: Standard Torque; Red: Super Torque scribe line help guide bracket placement. Whether you are starting to use self-ligation or are already an expert user, Damon Q will provide more controlled. Damon Q Bracket -Braces. damon lower brackets d3mx % dq % 2. a standard torque Damon Q central incisor bracket w it+ 1 5º ofrqu elyp ca s 0. Follow an exacting bracket placement protocol to protect or enhance the smile arc and align buccal segment cusp tips and marginal ridges. 0 20 7 92 3-3 high t. 8 – 14. Lima is a Professor, Darwin Dentistry Institute, Cuiabá. It is completely reengineered to virtually eliminate play for precise control of rotation, angulation and torque. 45 Nmm. Cashback 5%. , Glendora, CA 91740-0000) is a passive self-ligation system that was. 016″ round demonstrated +12% teeth correction in 10% less time in Damon Q brackets versus Ti Orthos. Orthodontic therapy with fixed appliances using the straight-wire technique has gained popularity nowadays due to its advantages, including a shorter treatment time, greater comfort for the patient and better control of the position of the teeth in the three planes of space []. Designed with twice the rotation control (U3-3 compared to original DQ bracket), the bracket boasts a small profile and smooth rounded corners, for improved patient comfort and aesthetics. 31 Nmm with 0. • The Damon philosophy is based on the principle of using just enough force to initiate tooth movement—the threshold force. 016 ligature wire. There is 9° play between 19 × 25 stainless steel archwires and the Damon bracket slot creates the Multiloop Edgewise Archwire effect which is effective in treating open bites, severe Class IIs, and Class IIIs, and asymmetry patients, without bending complicated loops. 025” dimension to 0. Damon Torque and Bracket Placement Guide PDF Dentistry Branches Dentistry. 2. Made from easily adaptable . 1996. 019 × 0. Nine years after Ormco Corp, Orange, Calif, unveiled the Damon™ Q bracket, orthodontists finally have the answer to what’s next: the Damon™ Q2 (DQ2). Duncan Brown, Dr. 125:645-6, 2004. The main advantage of the Damon System is, when you think of traditional braces, wire slides into a metal bracket that was held on only by a strong rubber band. and . Among the archwires, 0. Combining reliable Damon ™ bracket features with the convenience of ample under tie-wing area and greater rotational control, Damon ™ Q2 offers the versatility to efficiently treat ALL of your cases with simplified mechanics. The result is a crystal-clear appliance that goes beyond all aesthetic and functional expectations. Article. A chemical/steam indicator. 1-1. Ad. Additionally, some studies find that Damon braces are more efficient than traditional braces, but all in all, both methods are very successful. Tom Pitts’ Bracket Placement – Hands-on Dr. 1996. sk@gmail. 45 Nmm, while Smart Clip brackets generated 22. The final plan included the following: (1) no extractions or orthognathic surgery; (2) Damon Q brackets (Ormco, Glendora, Calif): standard torque passive self-ligating brackets bonded upside-down on the maxillary canines, lateral incisors, and central incisors to resist the flaring effect of Class III elastics; (3) open-coil springs between the. • The generic term is. fall into the range 4-50 pounds. Watch Video. Moreover, considering inexperienced students in the beginning of their orthodontic clinical training, the accurate direct bracket placement procedure can be even more challenging,Cal Poly. 4 October–December 2008: 173 − 178Representing over 20 years of innovation and inspiration from orthodontists around the world, the new Damon™ Q2 is the 8th generation bracket in the world-renowned Damon™ System— a proven combination of passive self-ligating brackets, light force archwire sequencing, and recommended treatment protocols used to successfully finish millions of. 4. 3 The Protocol - Thomas Pitts Bracket Positioning for Smile Arc Protection - Thomas Pitts. For proper bracket positioning, three dimensions must be considered: 1. • Damon Q brackets have a horizontal auxiliary slot which permits a low- friction application of piggyback archwires for. Therefore, the table is named Guide Position Smile-Arc (GPS-A). 014 or . txt) or read online for free. Allows for convenient placement of drop-in hooks. The demonstration experiment shows that a Damon Q bracket had a final plastic deformation after a single loading of 0. The ultimate aesthetic offering for your patients. Modern Self-ligating Brackets Passive in the leveling and alignment stages and active during major. A, Process of bracket placement on a digital model (using FA point. 1. 033"*. This test allowed evaluating whether there is a correlation between resistance to sliding and brackets surface roughness. Bracket Height. *Corresponding author. Offering a complete and interchangeable system of metal and aesthetic appliances, Damon™ Q2 functions seamlessly with: Damon™ Q brackets, Damon™ Clear2 brackets, SnapLink™ buccal tubes, Accent™ Mini. Consumables. Materials/methods: Two tables, one for upper dentition and one for lower dentition were designed to guide the bracket placement, in order to obtain or retain the best esthetic In this case to better visualize the final bracket placement, the pano/repo was performed at 15 months (Figure 6) after most space was closed and all major mechanics complete. 21 x 0. A, Process of bracket placement on a digital model (using FA point. txt) or read online for free. Pure Slide Passive Self-Ligating Metal Brackets Upper/Lower 7-7 [28/per set]Research has shown that most brackets have oversized slots. 3 & 4 Std. Brendan Cooney. The indirect bonding appointment will be completed by the assigned resident, at which time the. Removable positioning gauge with scaler notch and rhomboid-shaped bracket and pad guide bracket placement for smile arc enhancement. Brackets Placement. The main advantage ofWe used 0. The Damon Ultima System is the first true full expression orthodontic system designed for faster and more precise finishing. Braces are a type of appliance that use pressure to adjust the positioning of your teeth and jaw. 45 Nmm, while Smart Clip brackets generated 22. 025 SS Upper (pre-posted) . Notes on Bracket Placement ! Pre-adjusted appliances are only as good as the accuracy of bracket placement. Lima Dr. Studies have shown that a fuller smile, with a wider arch, is more attractive. 016 x . Comparison of . m. Damon’s self-ligating brackets have been designed to overcome the drawbacks of conventional bracket system and are often considered as the pinnacle of bracket technology. Downloads. Upper . Offering a complete and interchangeable system of metal and aesthetic appliances, Damon™ Q2 functions seamlessly with: Damon™ Q brackets, Damon™ Clear2 brackets, SnapLink™ buccal tubes, Accent™ Mini buccal tubes, and Titanium buccal tubes. 26 – 70. 5 mm from incisal edge Max. InstrumentMany bracket systems are available in the present phase of orthodontics in which Self Ligating Bracket (SLB) system is one. With this product release, Ormco is introducing a fully reengineered bracket and wire integrated system—what the company is calling “the first true full-expression orthodontic system. Alexander further modified the Lewis bracket by adding a power arm. The Damon® 3 System uses a self-ligation technique using lighter wires and lower friction brackets to move teeth. Damon braces may be more hygienic than traditional braces. Advantages Rhomboid-shaped pad and new vertical scribe line help guide bracket placement. 013 Cu NiTi. Downloads. , 3M Unitek; Ovation C, 0. The wall shape found in Damon brackets was parallel. 1. 31 Nmm with 0. SKU: BKOAL Categoría: Brackets. Paired with a rhomboid-shaped pad and new vertical. Studies have shown that a fuller smile, with a wider arch, is more attractive. User Guide Journal List; J Clin Exp Dent. 2-14-11 Placed Damon Q™ brackets U 5-5, L 5-5. The new DQ2 drop-in hook4 was designed. 1 +2x U3-3 compared to original DQ bracket. Copenhagen, January 17, 2017 – 3Shape announces its Indirect Bonding solution now integrates with the Damon™ System Bracket library by Ormco Corporation. Comparing PAR. Join the conversationMetal brackets: Cure the adhesive by positioning the light guide mesial and distal t o each bracket. The MP model was. This indicates that the Speed bracket plastically deforms 3. We have a better control with. In creating extraordinary esthetic enhancement through orthodontic. The Damon System (Ormco Corp. Damon Clear 2 combines the properties of low friction passive self-ligating technology with the aesthetics that image-conscious patients demand. Ormco, Damon Company keeps evolving over the years, coming out with different and more compatible bracket systems. 2 times more than the Damon Q bracket for similar magnitude of applied moment. Instrument5 4 3 2 1 5 1 4 2 3 2 4 1 5 *Colored ID dots are located on tie-wings of each bracket. 022”), 15° torque prescriptions, angulations of 5°, and rotations of 0°. We have variety of brackets with standard, lower andHands-on placement of Damon Q brackets using protocols established by Dr. Lower arch; a . Thirty-two independent clinical evaluators bonded 1,098 brackets on 183 patients comprised of both adolescents and adults. Vertical scribe line, new drop-in hook and modified prescription —DQ2 features a rhomboid-shaped pad and new vertical scribe line to guide desired bracket placement. Damon Q brackets generated the highest torquing moment of 25. Technologic Advancements. By Alison Werner. Damon Technique (DT) Damon proposed a hypothesis in which low friction and light forces equally distribute expansion forces, resultingDamon Q bracket system were selected The patients with cleft lip and palate, tooth out of arch and patients requiring expansion or contraction of the arches were excluded. Description. Ormco Kit Damon Q U/I Torque Alto $ 5,944. Torquing moments decreased for Damon Q and Smart Clip. Self-Ligating bracket design. Upper . Bracket Placement Beethoven Orthodontic Clinic currently uses two types of brackets, Damon Q® and Damon Clear® (ceramic brackets of anterior teeth and maxillary premolars). At each increment, the bracket would be rotated 0. txt) or read online for free. BRACKET PLACEMENT GUIDE. 9. Pitts 21 is more than a set of brackets – it is a whole new method with specific protocols to create wide, beautiful 12-tooth smiles, as opposed to narrow 6-tooth smiles. The objective of this paper is a case. pad) occlusal - gingival (tie wing. Combining reliable Damon™ bracket features with the convenience of ample under tie-wing area and greater rotational control, Damon™ Q2 offers the versatility to efficiently treat ALL of your cases with simplified mechanics. bracket slide. Fixed appliances: OrmcoDamon Clear + Damon Q . The Damon System Bracket library joins more than 150 original bracket libraries and orthodontic solution providers now integrated with the 3Shape orthodontic software. At 15 months, a . Materials and Methods: A sample of 60 patients treated with all four first premolar extraction, using Damon Q bracket system were selected from the Department of Orthodontics. 1741 • 714. Quintessential performance and reliability. 1. Mini Diamonds offer the same benefits in regard to accurate bracket placement as their traditional counterparts plus: • Improved aesthetics and hygiene with a 30% reduction in overall bracket size. Comparison of . A crystal-clear transparent bracket that goes beyond all aesthetic and functional expectations. * Current Damon Q drop-in hooks (242-0114) are compatible with Damon Q2 brackets. Combining reliable Damon ™ bracket features with the convenience of ample under tie-wing area and greater rotational control, Damon ™ Q2 offers the versatility to efficiently treat ALL of your cases with simplified mechanics. 1 The Damon philosophy is based on the principle of using just enough force to initiate tooth movement—the threshold force. Cemented AdvanSync 2, crowns on U & L 1st molars. p. from publication: The Value of Self-Ligating Brackets in Orthodontics: About the Damon. ”. 019 × 0. 3rd session | Brackets placement and torque selection and the concept of the smile arc. More information. Self-ligating braces are a specialized bracket system that have become increasingly popular over the last 20 years. Convenient. Methods Using the equations developed in part 1 (eU1(BOP) = 90° − BT(U1) − TCA(U1) + α1 − α2 and eL1(BOP) = 90° − BT(L1) −. Here are some differences between Damon braces and traditional braces: Design: Traditional braces use metal brackets attached to the teeth with wires tightened over time to shift the teeth into place gradually. 0 20 7 92 3-3 high t. Tips & considerations Consider initiating adhesive cure by tacking each bracket on the gingival seamStandard bracket placement by Dwight Damon [18]: According to him, the arch wire slot should be at the distances mentioned below from the incisal edge. Damon. Precision bracket placement. 022-in Damon Q brackets (Ormco, Glendora, Calif) in this study. 0005) and more Damon 2 brackets debonded during the study (P, . • Carriere LX Ortho Technology • Damon MX • Smartclip™ Damon Q • Discovery™ • Vision LP American Ortho Dentauraum 15. When 014 and 016 NiTi archwires are tested in vitro using multiple brackets,. Join the conversationThe Score 2 results for both the MBT brackets and Damon brackets are 10%. InstrumentPerio & Surgery. Damon 3MX.